Repair And Rehabilitation of RCC Structure

(A) BY MANUAL REPAIR : Chipping and exposing the rebar, removing corrosion and salt present and treating the rebars and introducing additional rebar for the loss of steel quantity by welding and covered with polymer modified cement concrete and finished with polymer modified cement mortar.

(B) BY GUNITING/SHOT CRETING : Chipping and exposing the rebar,removing the corrosion and salt present and treating the rebars and introducing additional rebar for the loss of steel quantity by welding and covered with high pressure guniting/shotcrete method with polymer modified concrete /mortar. and finished with polymer modified cement Plaster.